Powerful Cavity Ring-Down Gas Analyzer
Trace Level Gas Analyzer HALO3 series

TO01 Quotation・Inquiry
  • Outline
  • Specification
  • Related Documents
Trace Level Gas Analyzer HALO3 series Trace Level Gas Analyzer HALO3 series

Summary

Based on Cavity Ring-Down Spectroscopy (CRDS), TigerOptics HALO3 series can measure the sub-ppb level of gas species with absolute accuracy, proven reliability, and fast response in one compact and easy-to-use device.

Application

  • Quality control for laboratory analysis
  • Gas and chemical manufacturing
  • R&D of moisture analysis and moisture standard

Features

  • NIST traceable
  • High sensitivity, high accuracy, high reliability, high speed of response
  • Compact, ease of operation, no periodic replacement/maintenance
  • Analyte: H2O, CO, CO2, CH4, HF, etc.
  • Gas analysis over a vast range, H2O in N2 : 400ppt~20ppm (HALO KA H2O)
  • Ethernet, isolated 4-20 mA and RS-232 connectivity

Cavity Ring-Down Spectroscopy(CRDS)

1.A Continuous Wave (CW) diode laser emits a directed beam of light energy through an ultra-high reflective mirror into the absorption cell (cavity).

2.The light reflects back and forth between two ultra-high reflective mirrors multiple times, up to a total path length of 100 kilometers.

3.Once the photodiode detector “sees” a preset level of light energy, the light source is shuttered or diverted from the cavity.

4.On each successive pass, a small amount of light or ring-down signal emits through the second mirror and is sensed by the light detector.

5.Once the light "rings down", the detector achieves a point of zero light energy in milliseconds, and the measurement is complete.

Ring-Down Cavity Cell

Fig 1. Ring-Down Cavity Cell

Ring-Down Time

Fig 2. Ring-Down Time

Performance

Operating range See table below
Detection limit(LDL,24h peak-to-peak variation) See table below
Sensitivity(3σ) See table below
Precision(1σ,greater of) ± 0.75 % or 1/3 of Sensitivity
Accuracy(greater of) ± 4 % or 1/2 of LDL
Speed of response See table below
Environmental conditions 10℃~40℃
30%~80% RH(non-condensing)
Storage temperature -10℃~50℃

Gas Handling System and Conditions

Wetted materials 316L stainless steel (Optional Hastelloy)
10 Ra surface finish
Gas connections 1/4” male VCR inlet and outlet
Inlet pressure 10~125 psig (1.7~9.6 bara)
Flow rate 0.05~1.8 slpm (gas dependent)
Sample gases Most inert、toxic、and、passive matrices
Gas temperature Up to 60 ℃

Dimensions and Weight

Standard sensor
H×W×D [in (mm)]
8.75×8.5×23.6 (222×216×599)
Sensor rack
H x W x D [in (mm)]
8.75×19×23.6 (222×483×599)
(fits up to two sensors)
Weight,Standard sensor 28 lbs (12.7 kg)

Electrical

Alarm indicators 2 user programmable
1 system fault
Form C relays
Power requirements 90~240VAC
50/60Hz
Power consumption 40 Watts max.
Signal output Isolated 4-20mA persensor
User interfaces 5.7"LCD touchscreen
10/100Base-TEthernet
802.11gWireless(optional)
RS-232

HALO KA H2O

Analyte Range LDL Sensitivity Speed of response
H2O in N2 0~20ppm 400ppt 300ppt 3 min to 95 %
H2O in He 0~4ppm 200ppt 60ppt
H2O in Ar 0~9ppm 200ppt 130ppt
H2O in O2 0~16ppm 300ppt 200ppt
H2O in H2 0~10ppm 200ppt 150ppt

HALO 3Q H2O

Analyte Range LDL Sensitivity Speed of response
H2O in N2 0~20ppm 0.8ppb 0.6ppb 3 min to 95 %
H2O in He 0~4ppm 0.25ppb 0.12ppb
H2O in Ar 0~9ppm 0.4ppb 0.3ppb
H2O in O2 0~16ppm 0.6ppb 0.4ppb
H2O in H2 0~10ppm 0.4ppb 0.3ppb

HALO 3 H2O

Analyte Range LDL Sensitivity Speed of response
H2O in N2 0~20ppm 1.5ppb 1.2ppb 3 min to 95 %
H2O in He 0~4ppm 0.3ppb 0.25ppb
H2O in Ar 0~9ppm 0.7ppb 0.6ppb
H2O in O2 0~16ppm 1.2ppb 1.0ppb
H2O in H2 0~10ppm 0.9ppb 0.7ppb

HALO 3 H2O 500

Analyte Range LDL Sensitivity Speed of response
H2O in N2 0~500ppm 10ppb 8ppb 3 min to 95 %
H2O in He 0~125ppm 5ppb 4ppb
H2O in Ar 0~200ppm 8ppb 6ppb
H2O in O2 0~400ppm 8ppb 6ppb
H2O in H2 0~250ppm 10ppb 8ppb

Other HALO3 series

Model/Analyte Range※ LDL※ Sensitivity※ Speed of response
HALO3 CO/CO 0~2000ppm 100ppb 70ppb 1min to 90 %
HALO3 CO2 Low range/CO2 0~12ppm 10ppb 7ppb 3min to 95 %
HALO3 CO2 High range/CO2 0~1500ppm 300ppb 250ppb 1min to 90 %
HALO3 CH4/CH4 0~8ppm 2.0ppb 1.6ppb 3min to 95 %
HALO3 HF/HF 0~5ppm 0.5ppb 0.4ppb 1min to 90 %

※In N2 gas

Get ADOBE READER

Adobe Reader is required to view the downloaded PDF files.
Please download it from the left banner and install it.

Last Updated Update Information Size Download

Frequently Asked Questions

Quotation・Inquiry

* Please give us an Inquiry No.TO01

Telephone *Please give us an Inquiry No.
Head Office 81-3-3686-4711
Osaka Office 81-6-6393-7411